کليد هوایی اشنایدر الکتریک 1000 آمپر سه پل کشویی سری NW قدرت قطع 100kA

تماس بگیرید

کد محصول:: NW10H23P2AF

circuit breaker Masterpact NW10H2 – 1000 A – 3 poles – fixed – w/o trip unit   48016   کليد هوایی 1000 آمپر سه پل کشویی سری NW قدرت قطع 100kA NW10H23P2AF میکرولوجیک 2 Main range of product Masterpact NW product or component type Basic frame device short name Masterpact NW10 circuit breaker name Masterpact NW10H2 poles description 3P network type AC breaking capacity code H2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category B Complementary network frequency 50/60 Hz control type Push-button mounting mode Fixed [In] rated current 1000 A at 40 °C [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2 [Icm] rated short-circuit making capacity 187 kA 525 V AC at 50/60 Hz 187 kA 690 V AC at 50/60 Hz [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 circuit breaker CT rating 1000 A breaking capacity 85 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 85 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 protection type Without protection mechanical durability 12500 cycles without maintenance conforming to IEC 60947-2 25000 cycles with maintenance conforming to IEC 60947-2 electrical durability 10000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 10000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-23A: 10000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-23A: 10000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 AC-3: 6000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 connection pitch 115 mm [Icw] rated short-time withstand current 50 kA 3 s conforming to IEC 60947-2 85 kA 1 s conforming to IEC 60947-2 integral instant protection 171…209 kA maximum breaking time 25 ms maximum closing response time 70 ms height 352 mm width 422 mm depth 297 mm Environment standards IEC 60947-2 product certifications ASTA ASEFA pollution degree 4 conforming to IEC 60664-1 ambient air temperature for operation -25…70 °C ambient air temperature for storage -40…85 °C

توضیحات

circuit breaker Masterpact NW10H2 – 1000 A – 3 poles – fixed – w/o trip unit

 

48016

 

کليد هوایی 1000 آمپر سه پل کشویی سری NW قدرت قطع 100kA

NW10H23P2AF

میکرولوجیک 2

Main
range of product
Masterpact NW
product or component type
Basic frame
device short name
Masterpact NW10
circuit breaker name
Masterpact NW10H2
poles description
3P
network type
AC
breaking capacity code
H2
suitability for isolation
Yes conforming to IEC 60947-2
utilisation category
Category B
Complementary
network frequency
50/60 Hz
control type
Push-button
mounting mode
Fixed
[In] rated current
1000 A at 40 °C
[Ui] rated insulation voltage
1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
12 kV conforming to IEC 60947-2
[Icm] rated short-circuit making capacity
187 kA 525 V AC at 50/60 Hz
187 kA 690 V AC at 50/60 Hz
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
circuit breaker CT rating
1000 A
breaking capacity
85 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
85 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
protection type
Without protection
mechanical durability
12500 cycles without maintenance conforming to IEC 60947-2
25000 cycles with maintenance conforming to IEC 60947-2
electrical durability
10000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
10000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 10000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 10000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-3: 6000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
connection pitch
115 mm
[Icw] rated short-time withstand current
50 kA 3 s conforming to IEC 60947-2
85 kA 1 s conforming to IEC 60947-2
integral instant protection
171…209 kA
maximum breaking time
25 ms
maximum closing response time
70 ms
height
352 mm
width
422 mm
depth
297 mm
Environment
standards
IEC 60947-2
product certifications
ASTA
ASEFA
pollution degree
4 conforming to IEC 60664-1
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-40…85 °C