کليد هوایی اشنایدر الکتریک 1250 آمپر سه پل کشویی سری NW قدرت قطع 65KA

تماس بگیرید

کد محصول:: NW12H13P2AD

circuit breaker Masterpact NW12N1 – 1250 A – 3 poles – drawout – w/o trip unit   48258   کليد هوایی 1250 آمپر سه پل کشویی  سری NW قدرت قطع 65KA NW12H13P2AD Main range of product Masterpact NW product or component type Basic frame device short name Masterpact NW12 circuit breaker name Masterpact NW12N1 poles description 3P network type AC breaking capacity code N1 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category B Complementary network frequency 50/60 Hz control type Push-button mounting mode Drawout [In] rated current 1250 A at 40 °C [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2 [Icm] rated short-circuit making capacity 187 kA 525 V AC at 50/60 Hz 187 kA 690 V AC at 50/60 Hz [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 circuit breaker CT rating 1250 A breaking capacity 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2 protection type Without protection mechanical durability 12500 cycles without maintenance conforming to IEC 60947-2 25000 cycles with maintenance conforming to IEC 60947-2 electrical durability 10000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 10000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 connection pitch 115 mm [Icw] rated short-time withstand current 22 kA 3 s conforming to IEC 60947-2 42 kA 1 s conforming to IEC 60947-2 maximum breaking time 25 ms maximum closing response time 70 ms height 439 mm width 441 mm depth 394.5 mm Environment standards IEC 60947-2 product certifications ASEFA ASTA pollution degree 4 conforming to IEC 60664-1 ambient air temperature for operation -25…70 °C ambient air temperature for storage -40…85 °C

توضیحات

circuit breaker Masterpact NW12N1 – 1250 A – 3 poles – drawout – w/o trip unit

 

48258

 

کليد هوایی 1250 آمپر سه پل کشویی  سری NW قدرت قطع 65KA

NW12H13P2AD

Main
range of product
Masterpact NW
product or component type
Basic frame
device short name
Masterpact NW12
circuit breaker name
Masterpact NW12N1
poles description
3P
network type
AC
breaking capacity code
N1
suitability for isolation
Yes conforming to IEC 60947-2
utilisation category
Category B
Complementary
network frequency
50/60 Hz
control type
Push-button
mounting mode
Drawout
[In] rated current
1250 A at 40 °C
[Ui] rated insulation voltage
1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
12 kV conforming to IEC 60947-2
[Icm] rated short-circuit making capacity
187 kA 525 V AC at 50/60 Hz
187 kA 690 V AC at 50/60 Hz
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
circuit breaker CT rating
1250 A
breaking capacity
42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
protection type
Without protection
mechanical durability
12500 cycles without maintenance conforming to IEC 60947-2
25000 cycles with maintenance conforming to IEC 60947-2
electrical durability
10000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
10000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
connection pitch
115 mm
[Icw] rated short-time withstand current
22 kA 3 s conforming to IEC 60947-2
42 kA 1 s conforming to IEC 60947-2
maximum breaking time
25 ms
maximum closing response time
70 ms
height
439 mm
width
441 mm
depth
394.5 mm
Environment
standards
IEC 60947-2
product certifications
ASEFA
ASTA
pollution degree
4 conforming to IEC 60664-1
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-40…85 °C