کليد هوایی 1000 آمپر سه پل کشویی سری NT قدرت قطع 42kA

تماس بگیرید

کد محصول:: NT10H13P2AD

کليد هوایی 1000 آمپر سه پل کشویی سری NT قدرت قطع 42kA

circuit breaker Masterpact NT10H1 – 1000 A – 3 poles – drawout – w/o trip unit

توضیحات

کليد هوایی 1000 آمپر سه پل کشویی سری NT قدرت قطع 42kA

47220 –کليد هوایی 1000 آمپر سه پل کشویی سری NT  قدرت قطع 42kA 

NT10H13P2AD  – میکرولوجیک 2

circuit breaker Masterpact NT10H1 – 1000 A – 3 poles – drawout – w/o trip unit

range of product
Masterpact NT
product or component type
Basic frame
device short name
Masterpact NT10
circuit breaker name
Masterpact NT10H1
poles description
3P
network type
AC
breaking capacity code
H1
suitability for isolation
Yes conforming to IEC 60947-2
utilisation category
Category B
Complementary
network frequency
50/60 Hz
control type
Push-button
mounting mode
Drawout
[In] rated current
1000 A at 40 °C
[Ui] rated insulation voltage
1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
12 kV conforming to IEC 60947-2
[Icm] rated short-circuit making capacity
88 kA 220/415 V AC at 50/60 Hz
88 kA 440 V AC at 50/60 Hz
88 kA 525 V AC at 50/60 Hz
88 kA 690 V AC at 50/60 Hz
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
circuit breaker CT rating
1000 A
breaking capacity
42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
protection type
Without protection
mechanical durability
12500 cycles without maintenance conforming to IEC 60947-2
electrical durability
3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-3: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
connection pitch
70 mm
[Icw] rated short-time withstand current
24 kA 3 s conforming to IEC 60947-2
42 kA 0.5 s conforming to IEC 60947-2
42 kA 1 s conforming to IEC 60947-2
maximum breaking time
25 ms
maximum closing response time
50 ms
height
322 mm
width
288 mm
depth
276.5 mm
Environment
standards
IEC 60947-2
product certifications
LCIE
ASEFA
pollution degree
3 conforming to IEC 60664-1
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-40…85 °C
Offer Sustainability
Sustainable offer status
Green Premium product
EU RoHS Directive
Compliant
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
Contractual warranty
Warranty
18 months